18 S allfluid
0 ... 800 bar
Technical Data
Fluid:
For neutral and aggressive gases or fluids
Fluid connection: G 1/4 female with nipple manometer
connection
Mounting position: Optional
Weight: 0,070 kg
Fluid temperature: -20 °C ... +85 °C / -40 °C ... +120 °C *
Ambient temperature:
-20 °C ... +85 °C / -40 °C ... +120 °C *
Interference emission: EN 50081-1
Interference immunity: EN 50082-2
Degree of protection (acc. to DIN 40050)
IP 65 (with mounted plug)
Shock protection:
30g, xyz, to DIN EN 60068-2-27
Vibration protection:
3g, 5 ... 500 Hz, xyz, DIN EN 60068-2-6
Supply voltage:
12 ... 30 VDC (current output)
15 ... 30 VDC (voltage output)Residual ripple (max.):
10% (within supply voltage) at 50 Hz
Output signal:
4 ... 20 mA (Two-wire technology)
0 ... 10 Volt (Three-wire technology)
Frequency output*
Load resistance:
See diagram
Electrical connection:
M 12 x 1 / cable*
Polarity:
Short-circuit proof
Measuring range: See table overleaf
Linearity:
± 0.5% (final value)
Hysteresys:
< ± 0.1%
Temperature sensitivity:
Zero point < ± 0.4% FS / 10K
Range < ± 0.2% FS / 10K
Materials:
Housing Stainless steel 1.4571 / 1.4542
Sensor Stainless steel membrane 1.4542