11-808 Series

11-808 Series

11-808 Series

G3/4-G1

Technical Data

Fluid: Compressed air only (pilot and pilot operated regulators
have constant bleed)
Maximum pressure: 20 bar (290 psig)
Operating temperature: -20° to +80°C (-4° to +175°F) *
* Air supply must be dry enough to avoid ice formation at temperatures
below +2°C (+35°F).
Approximate flow (conventional pilot) with 8 bar (120 psig) inlet
pressure, 6,3 bar (90 psig) outlet pressure and pressure
droop of 1 bar (15 psig) from set:
160 dm3/s (340 scfm)
Approximate flow (feedback pilot) with 8 bar (120 psig) inlet
pressure, 6,3 bar (90 psig) outlet pressure and zero
pressure droop:
180 dm3/s (380 scfm)
Gauge ports: Rc 1/8
Pilot port: Rc 1/4

Pilot Regulators
Conventional:
11 400/20AL-X
Feedback:
11-204 high flow applications and remote sensing. Can only
be used in conjunction with a pilot operated regulator.

Materials:
Pilot operated regulators:
Body: Zinc
Bonnet: Aluminium
Valve: Brass
Elastomeric materials: Nitrile
Pilot regulators:
Body: Zinc
Bonnet: Zinc
Handwheel: Acetal resin
Valve: Brass
Elastomeric materials: Nitrile